Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Intervalo de año de publicación
1.
Biosci. j. (Online) ; 38: e38056, Jan.-Dec. 2022. tab
Artículo en Inglés | LILACS | ID: biblio-1396538

RESUMEN

The aim of this randomized double-blinded study was to evaluate the enamel surface roughness and color change after one month of whitening toothpaste use and the color stability obtained 1 month after its interruption. 30 volunteers were divided into 3 groups (n = 10) corresponding to the dentifrices: 1) Colgate Total 12 Clean Mint (TD) (Control), 2) Colgate Luminous White (LW) and 3) Sensodyne Whitening Extra Fresh (SB). The volunteers were impression with addition silicone to obtain an epoxy resin replica of the upper central incisor for the initial surface roughness evaluation using a profilometer and the initial color of the incisors and canines was evaluated with a spectrophotometer after one week of wash-out. After 1 month, the color of the central incisors and canines was measured again, and the volunteers were molded to obtain a second replica to the final roughness analysis. Data were submitted to ANOVA-one way (p≤0.05). The results showed that there was no statistical difference between the dentifrices for color difference and surface roughness for all the studied conditions. It was possible to conclude that the whitening dentifrices used in this study were not able to alter the initial color of the teeth and did not cause changes in the surface roughness of enamel.


Asunto(s)
Blanqueamiento de Dientes , Color , Esmalte Dental , Dentífricos
2.
Rev. odontol. UNESP (Online) ; 49: e20200022, 2020. tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1139428

RESUMEN

Introduction: To prevent the shrinkage stresses produced during polymerization, composite resins of low polymerization shrinkage were developed. Objective: To evaluate the microtensile bond strength in class I cavities restored by acid-etching the cavosurface angle and with composite resins indicated for posterior teeth. Material and method: 48 healthy molars were selected and divided into six groups (n = 8), considering that the cavosurface enamel of three groups was etched with 35% phosphoric acid. The teeth were restored with the Clearfil SE Bond adhesive system and Filtek Z350 XT, Empress Direct, and Charisma Diamond composite resins, which were light-cured for 40 seconds. After 24 hours, the teeth were taken to a cutting machine, which produced sections in the buccolingual and mesiodistal directions. This resulted in toothpicks of 0.9×0.9 mm that were taken to the universal testing machine for the microtensile bond strength test. Statistical analysis was performed with ANOVA and Tukey's test (p < 0.05). Result: There was no statistically significant difference between the groups evaluated. Conclusion: Acid-etching the cavosurface angle did not affect the performance of restorations, probably due to the adhesive system used.


Introdução: Com o intuito de se evitar as tensões geradas durante a contração de polimerização das resinas compostas, foram desenvolvidas as resinas compostas de baixa contração de polimerização. Objetivo: Avaliar a resistência à microtração em cavidades classe I restauradas com tratamento ácido do ângulo cavo superficial e resina composta indicada para dentes posteriores. Material e método: Foram selecionados 48 molares hígidos que foram divididos em 6 grupos (n=8), sendo que 3 desses tiveram o esmalte cavo superficial condicionado com ácido fosfórico a 35%. Os dentes foram restaurados com o sistema adesivo Clearfil SE Bond e as resinas compostas Filtek Z350 XT, Empress Direct e Charisma Diamond, fotoativadas por 40 segundos. Após 24 horas, os dentes foram levados para máquina de corte, na qual foram realizados cortes no sentido vestíbulo-lingual e no sentido mésio-distal obtendo - se palitos de 0,9×0,9 mm que foram levadas para a máquina de ensaio universal para a realização do teste de microtração. Para análise estatística foi realizado análise de variância e teste de Tuckey (p < 0,05). Resultado: Não houve diferença estatística significante entre os grupos avaliados. Conclusão: O condicionamento ácido do ângulo cavo superficial não influenciou no desempenho das restaurações provavelmente devido ao sistema adesivo utilizado.


Asunto(s)
Análisis de Varianza , Resinas Compuestas , Preparación de la Cavidad Dental , Curación por Luz de Adhesivos Dentales , Dureza , Diente Molar , Restauración Dental Permanente
3.
Gen Dent ; 67(6): e1-e5, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31658032

RESUMEN

The objective of this study was to evaluate the effect of the simplified ethanol wet-bonding technique on luting of posts to intraradicular dentin. The effect was assessed by push-out bond strength testing and confocal laser scanning microscopic analysis. Thirty endodontically treated roots were distributed into 3 groups (n = 10): water wet-bonding; stepwise ethanol wet-bonding; and simplified ethanol wet-bonding. After cementation of the posts, the roots were sectioned. Specimens were stored for 24 hours or 1 year before they were stressed to failure. Specimens from each group were processed for microscopic analysis. Data were analyzed using a 2-way analysis of variance and the Tukey test (α = 0.05). Statistically significant differences in push-out bond strength values were observed between the technique groups (P < 0.001) and between the storage periods (P = 0.009). The bond strength results in the group bonded using the simplified ethanol wet-dehydration approach did not differ from those in the group bonded using the stepwise ethanol technique at either storage time interval (P > 0.05). From 24 hours to 1 year, there was a similar decrease in bond strength for specimens prepared with the simplified and stepwise techniques. The microscopic results confirmed that ethanol wet-bonding technique improved the quality of the interface. The simplified ethanol wet-dehydration protocol achieved bond strengths and stability over time that were similar to those obtained with the stepwise ethanol technique and may be considered an alternative strategy to accomplish resin cement-root dentin bonding.


Asunto(s)
Recubrimiento Dental Adhesivo , Cavidad Pulpar , Recubrimientos Dentinarios , Técnica de Perno Muñón , Dentina , Etanol , Ensayo de Materiales , Cementos de Resina
4.
J Conserv Dent ; 21(1): 47-51, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29628647

RESUMEN

PURPOSE: The aim of this in vitro study was to evaluate the color stability and degree of conversion (DC) of dual-cure and light-cure cements and flowable composites after thermal aging. MATERIALS AND METHODS: A total of 50 human incisors were prepared and divided into six groups (n = 10). Veneers were fabricated using IPS Empress Direct composite resin were bonded with three types of luting agents: Light-cured, conventional dual, and flowable composite according to the manufacturer's instructions. The groups were as follows: Filtek Z350XT Flow/Single Bond 2, RelyX ARC/Single Bond 2, RelyX Veneer/Single Bond 2, Tetric N-Flow/Tetric N-Bond, and Variolink II/Tetric N-Bond. Commission Internationale de l'Éclairage L*, a* and b* color coordinates were measured 24 h after cementation procedure with a color spectrophotometer and reevaluated after 10,000 thermal cycles. To evaluate the DC 50 specimens (n = 10) of each resin material were obtained and Fourier transform infrared spectroscopy was used to evaluate the absorption spectra. Statistical analysis was performed with one-way ANOVA and Tukey's test (α = 0.05). RESULTS: No statistically significant differences in ΔE* occurred after aging. The greatest change in lightness occurred in the Variolink II resin cement. Changes in red-green hue were very small for the same cement and largest in the Tetric N-Flow flowable resin composite, while the greatest change in blue-yellow hue was a yellowing of the RelyX ARC luting cement. RelyX ARC exhibited the highest DC, and there were no statistically significant differences in DC among the other cements. CONCLUSIONS: Resin-based luting agent might affect the final of ceramic veneer restorations. The thermal aging affected the final color of the evaluated materials, and these were regarded as clinically unacceptable (ΔE >3.3).

5.
Braz. j. oral sci ; 16: e17059, jan.-dez. 2017. ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-883924

RESUMEN

The aim of this study was to evaluate how acid-etching of the cavosurface enamel in Class I resin composite restorations influences the bond strength to the pulpal wall and the restoration, Knoop microhardness and nanoleakage after thermomechanical aging. For this research 76 fresh human molars were selected and restored with Silorane or Clearfil SEBond/Z350XT composite divided in 4 groups (Silorane system restored with or without enamel cavosurface acid-etching and Clearfil SEBond/Z350XT with or without enamel cavosurface acid-etching). To induce artificial aging, samples were subjected to thermomechanical cycling through 200,000 and thermal cycling between 5 and 55 °C with 30 second filling and 15-second drainage steps. Microhardness and microtensile bond strength were evaluated in 32 teeth (n=8) each and nanoleakage evaluation was performed in 12 teeth (n=3). Samples restored by Clearfil SEBond/Z350 XT without cavosurface acid-etching showed significantly lower microtensile bond strength results. The resin composite Z350XT presented higher values of Knoop microhardness. It was observed little or no infiltration for Silorane groups and moderate infiltration for Clearfil SE Bond groups. Acid-etching of the cavosurface enamel during restoration procedure with Clearfil Se Bond resulted in a stronger bond after thermomechanical cycling. Silorane groups showed less infiltration than Clearfil SE Bond groups (AU)


Asunto(s)
Humanos , Adhesivos , Resinas Compuestas , Preparación de la Cavidad Dental , Resinas de Silorano , Resistencia a la Tracción
6.
Microsc Res Tech ; 80(8): 943-949, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28488772

RESUMEN

AIM: Evaluate the composite-to-enamel bond after passive or active application of self-etching primer systems on polished or pre-etched enamel with phosphoric acid. MATERIALS AND METHODS: Two self-etch adhesives systems (SEAS) were used: Clearfil SE Bond and Easy Bond. Third human molars were divided into 8 groups (N = 10). The crown of each tooth was sectioned into halves and the mesial/distal surfaces were used. The adhesives were actively or passively applied on enamel with or without prior phosphoric-acid etching. Resin composite cylinders were built after adhesive application. After stored in relative humidity for 24 hr/37°C the specimens were subjected to microshear test in universal testing a machine at a crosshead speed of 0.5 mm/minute. The results were analyzed with three-way ANOVA and the Tukey test. The enamel-etching pattern was evaluated under SEM. RESULTS: The 2-step SEAS system presented significantly higher adhesive bond strength means (47.37 MPa) than the 1-step (36.87 MPa). A poor enamel- etching pattern was observed in active mode showing irregular and short resin tags, however there was not compromised the bond strength. CONCLUSION: Active or passive application produced similar values of bond strength to enamel regardless of enamel pretreatment and type of SEAS.

7.
Gen Dent ; 63(3): 31-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25945761

RESUMEN

The aim of this in vitro study was to evaluate the nanoleakage of fiber posts luted using different adhesive strategies and to investigate the effect of 2% chlorhexidine (CHX) on nanoleakage at the resin-dentin interfaces of self-adhesive cements. The self-adhesive and etch-and-rinse adhesive groups tested demonstrated similar results with regard to nanoleakage. Pretreatment with CHX promoted an adequate seal at the resin-dentin interface for self-adhesive cements.


Asunto(s)
Clorhexidina/farmacología , Resinas Compuestas/uso terapéutico , Cementos Dentales/uso terapéutico , Filtración Dental/inducido químicamente , Dentina/metabolismo , Animales , Bisfenol A Glicidil Metacrilato/uso terapéutico , Bovinos , Polietilenglicoles/uso terapéutico , Ácidos Polimetacrílicos/uso terapéutico , Cementos de Resina/uso terapéutico
8.
J Esthet Restor Dent ; 26(4): 288-95, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24980900

RESUMEN

OBJECTIVES: The current study evaluated the effect of accelerated artificial aging (AAA) on the color stability (CS) and degree of conversion (DC) of nanofilled and nanohybrid resin composites associated to different adhesive systems in direct esthetic restorations. MATERIAL AND METHODS: Eighty bovine incisors were used to obtained dentin blocks (4 × 4 × 1 mm). The restorative systems were bonded to the blocks and photoactivated according to the manufacturer's instructions. Three adhesive systems were used: Adper Scotchbond Multi-Purpose (conventional of three steps), Tetric N-Bond (conventional of two steps) and ClearFill SE Bond (self-etching). Also, two composites were used: Filtek Z350 XT (nanofilled) and IPS Empress Direct (nanohybrid). The restorations were made using a silicone mold placed on top of the prepared dentin blocks (N = 10). CS was measured after 300 hours of AAA by means of ultraviolet light using a spectrophotometer and CIE L*a*b* parameters on the top surface of the composite and at the bonded interface. The DC was performed using Fourier transform infrared spectroscopy (N = 10). Data were analyzed using two-way analysis of variance and Tukey's test (α = 0.05). RESULTS: The adhesive systems had no significant influence on the color stability (ΔE) of either the restoration surface (α = 0.90) or the bonded interface (α = 0.78). However, composite influenced the color as measured by ΔE and isolated coordinates (α < 0.001). The nanohybrid composite showed increased DC values (67%) compared with the nanofilled (61%) with statistically significant differences (α < 0.001). CONCLUSIONS: The adhesive system did not affect the final color of direct esthetic restorations. The nanohybrid composite demonstrated a higher DC and increased color stability after AAA compared to the nanofilled composite. CLINICAL SIGNIFICANCE: The long-term color stability of composite restorations is a critical aspect of esthetic restorative procedures. Optimal Polymerization behavior of resin composite as indicated by the degree of conversion also influence on the color stability after artificial aging of composite restorations.


Asunto(s)
Color , Restauración Dental Permanente , Estética Dental , Polimerizacion , Resinas Compuestas , Espectrofotometría Ultravioleta
9.
Rev. bras. odontol ; 69(2): 250-254, Jul.-Dez. 2012. graf, tab
Artículo en Portugués | LILACS | ID: lil-720352

RESUMEN

A instrumentação dos canais radiculares através do uso de lima única em movimento recíproco vem se popularizando devido à redução do tempo de trabalho e menor tendência de fraturas dos instrumentos. Antes de escolher o sistema que vai utilizar, o cirurgião- -dentista deve conhecer as capacidades e limitações de cada sistema baseado em evidências científicas. Esse artigo realizou uma revisão de literatura sobre o movimento recíproco para instrumentação do sistema de canais radiculares apontando as vantagens e desvantagens da utilização dessa cinemática de instrumentação.


The canal’s instrumentation by using single file in reciprocation movement is gaining popularity due to the reduction of working time and less prone to fractures of the instruments. Before choosing which system will use, the dentist must know the capabilities and limitations of each system based on scientific evidence. This article reviews the literature on the reciprocation movement pointing out the advantages and disadvantages of this different kinematic instrumentation.


Asunto(s)
Raíz del Diente/lesiones , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Endodoncia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...